Skip to main content
tapwater
England and Wales average 9.2

Tap water in UB8, HillingdonSafe to drink.Very hard.

Supplied by Affinity Water. 1,294 samples, 24 substances, latest on 17 December 2025. Everything is inside the legal limit. One result, lead, sits close to the line.

8.6 / 10

The tank is as full as the score. The specks are the minerals that make water hard.

What to do about it

Hard water: compare softener quotes

At 306 mg/L a softener is the only thing that stops limescale. Filters do not soften water.

It pays for itself in most homes at this hardness, through a boiler that stays efficient and appliances that last.

Waterdrop G3P600 Reverse Osmosis

Waterdrop G3P600 Reverse Osmosis

£550typical price

Removes lead, the result that stood out in UB8.

Doulton HIS Push-fit with Biotect Ultra

Doulton HIS Push-fit with Biotect Ultra

£285typical price

Removes lead, the result that stood out in UB8.

We earn a commission if you buy through these links, at no extra cost to you. It never changes which product we put first. How we make money

Hear about it if UB8’s water changes

We check for supply incidents every fifteen minutes. If one affects UB8, you get an email the same day. You also get five short emails about your water over the first month.

Want this as a document?

Every result, the limits, hardness and what to do, as a PDF to keep with the house papers or send to a buyer or landlord. £19.99.

See the full report for UB8

What's in a glass of UB8 water

Every bubble is a substance the lab measured. The higher it floats, the closer it came to its legal limit, the dashed line at the top.

Lead came closest to a limit, at 82% of it. 18 of 21 substances used under a quarter of theirs.

0%25%50%75%limitLegal limitChromium: 0.000383 mg/L, <1% of the 0.05 mg/L limitChromium<1%Selenium: 0.000352 mg/L, <1% of the 0.04 mg/L limitSelenium<1%Cadmium: 0.000054 mg/L, 1% of the 0.005 mg/L limitCadmium1%Manganese: 0.00057 mg/L, 1% of the 0.05 mg/L limitManganese1%Copper: 0.034 mg/L, 2% of the 2 mg/L limitCopper2%Nitrite: 0.01 mg/L, 2% of the 0.5 mg/L limitNitrite2%Mercury: 0.000023 mg/L, 2% of the 0.001 mg/L limitMercury2%Turbidity: 0.1 NTU, 3% of the 4 NTU limitTurbidity3%Iron: 0.00897 mg/L, 4% of the 0.2 mg/L limitIron4%Boron: 0.046 mg/L, 5% of the 1 mg/L limitBoron5%Arsenic: 0.000515 mg/L, 5% of the 0.01 mg/L limitArsenic5%Antimony: 0.000327 mg/L, 7% of the 0.005 mg/L limitAntimony7%Fluoride: 0.131 mg/L, 9% of the 1.5 mg/L limitFluoride9%Colour: 2 mg/L Pt/Co, 10% of the 20 mg/L Pt/Co limitColour10%Nickel: 0.00219 mg/L, 11% of the 0.02 mg/L limitNickel11%Ammonia: 0.06 mg/L, 12% of the 0.5 mg/L limitAmmonia12%Bromate: 0.00182 mg/L, 18% of the 0.01 mg/L limitBromate18%Aluminium: 0.0411 mg/L, 21% of the 0.2 mg/L limitAluminium21%Trihalomethanes: 0.0334 mg/L, 33% of the 0.1 mg/L limitTrihalomethanes33%Nitrate: 30.5 mg/L, 61% of the 50 mg/L limitNitrate61%Lead: 0.00815 mg/L, 82% of the 0.01 mg/L limitLead82%
  1. Lead82%
  2. Nitrate61%
  3. Trihalomethanes33%
  4. Aluminium21%
  5. Bromate18%
  6. Ammonia12%
  7. Nickel11%
  8. Colour10%
  9. Fluoride9%
  10. Antimony7%
  11. Arsenic5%
  12. Boron5%
  13. Iron4%
  14. Turbidity3%
  15. Mercury2%
  16. Nitrite2%
  17. Copper2%
  18. Manganese1%
  19. Cadmium1%
  20. Selenium<1%
  21. Chromium<1%
  • E. coli none found
  • Coliform Bacteria none found
  • Conductivity 586 µS/cm
All 24 results as a table
SubstanceResultLegal limitShare of limit
Lead0.00815 mg/L0.01 mg/L
82%
E. coli0 count/100mlMust be zeroNone found
Selenium0.000352 mg/L0.04 mg/L
<1%
Iron0.00897 mg/L0.2 mg/L
4%
Turbidity0.1 NTU4 NTU
3%
Coliform Bacteria0 count/100mlMust be zeroNone found
Conductivity586 µS/cmNo legal limit–
Boron0.046 mg/L1 mg/L
5%
Arsenic0.000515 mg/L0.01 mg/L
5%
Cadmium0.000054 mg/L0.005 mg/L
1%
Mercury0.000023 mg/L0.001 mg/L
2%
Copper0.034 mg/L2 mg/L
2%
Colour2 mg/L Pt/Co20 mg/L Pt/Co
10%
Aluminium0.0411 mg/L0.2 mg/L
21%
Manganese0.00057 mg/L0.05 mg/L
1%
Bromate0.00182 mg/L0.01 mg/L
18%
Nickel0.00219 mg/L0.02 mg/L
11%
Trihalomethanes0.0334 mg/L0.1 mg/L
33%
Antimony0.000327 mg/L0.005 mg/L
7%
Chromium0.000383 mg/L0.05 mg/L
<1%
Fluoride0.131 mg/L1.5 mg/L
9%
Ammonia0.06 mg/L0.5 mg/L
12%
Nitrate30.5 mg/L50 mg/L
61%
Nitrite0.01 mg/L0.5 mg/L
2%

306mg of limescale minerals in every litre

This is the water that furs up kettles

Very hard on the UK scale. It is fine to drink. It is hard on boilers, showers, skin and anything that heats water, and a jug or tap filter will not change that.

Soft400 mg/L

Over 200 mg/L, the building regulations guidance for England counts this as a hard water area: a new combination boiler or water heater should have limescale protection. The 200 ppm rule

Softener quotes for UB8

Leave your details and we will email you when we can match you with installers who cover UB8. No obligation.

A fitted softener typically costs £1,195 to £2,900. Prices by brand, with sources. Request a free assessment and we'll come back to you with local installer options for your area.

UB8— auto-detected from your search

100%

free, no obligation

shared only with your consent

Outside your tap

Your river is the Pinn, rated moderate

The Environment Agency rated the Pinn as moderate for ecological health in its 2025 assessment, meaning the river is noticeably changed by pollution or engineering. It is held back by phosphate. It fails the chemical test, as every river, estuary and stretch of coast in England does, because of long-lasting pollutants such as mercury, PFOS (a forever chemical) and old flame retardants.

None of this is a test of your tap water. Environment Agency record · River health across England

UB8 in short

Tap water in UB8 (Hillingdon) is supplied by Affinity Water and scores 8.6 out of 10, against an England and Wales average of 9.2. 1 of 24 tested substances was close to or over a limit. The latest sample is from 17 December 2025.

  • Lead is within its legal limit but flagged, at 82% of the 0.01 mg/L maximumAnything over three quarters of a limit is flagged here as worth watching. It has not gone over. See every reading
  • The lowest score of the 9 areas tested in HillingdonUB8 scores 8.6 out of 10. The best in Hillingdon, TW6, scores 9.3.
  • Among the hardest water in the country at 306 mg/LVery hard starts at 250 mg/L. At this level kettles scale up within weeks and a softener is a normal purchase in UB8. How hardness is measured

Questions about UB8 water

Is UB8 tap water safe to drink?

Based on the latest tests, UB8 (Hillingdon) water scores 8.6/10, which is safe. 1 of 24 tested contaminants exceeded recommended levels. Water is supplied by Affinity Water.

What contaminants are in UB8 water?

We tested 24 contaminants in UB8 water. 1 were flagged, including Lead.

Who supplies water in UB8?

UB8 (Hillingdon) is supplied by Affinity Water. You can view their full profile and compliance data on our supplier page.

Is UB8 water hard or soft?

Water in UB8 (Hillingdon) has a hardness of 306 mg/L CaCO3, which is classified as very hard. Hard water can cause limescale buildup. A water softener or filter jug may help.

Should I use a water filter in UB8?

With 1 contaminant above recommended levels in UB8, a water filter could help. A filter jug or under-sink filter can reduce most common contaminants. See our filter recommendations for your area.

Are there PFAS forever chemicals in UB8 water?

No PFAS (forever chemicals) result is attached to the tap-water tests for UB8, and the Environment Agency has no PFAS detections in rivers or groundwater within 10 km of it. That reflects where sampling has happened as much as the water itself.

How clean is the river near UB8?

The Environment Agency rated the Pinn as moderate for ecological health in its 2025 assessment, meaning the river is noticeably changed by pollution or engineering. It is held back by phosphate. It fails the chemical test, as every river, estuary and stretch of coast in England does, because of long-lasting pollutants such as mercury, PFOS (a forever chemical) and old flame retardants. This is a rating of the river, not of tap water in UB8, which is treated before it reaches homes.

Keep reading

Lead in waterBoiling water taps and hard waterUnder sink water filtersHow to test your waterBest water filtersFilter shower headsWater testing kitsUK water rankingsWater hardness checkerWater hardness map

River and groundwater readings near UB8

Environment Agency samples from rivers, groundwater and reservoirs nearby. Not your tap water. For scale they are shown against drinking water limits; rivers are judged against much stricter environmental standards, and on those every river in England fails for chemicals.

SubstanceReadingDrinking water limit
pH7.95 pHNone
Temperature10.9 °CNone
Conductivity894 µS/cmNone
Nitrate16 mg/L50 mg/L
Nitrite0.021 mg/L0.5 mg/L
Phosphate0.3 mg/LNone
Dissolved Oxygen10.1 mg/LNone
Ammonia0.033 mg/L0.5 mg/L

Source: Affinity Water test results, published through the Stream Water Data Portal; rivers and PFAS from the Environment Agency. Page updated . How we score · Where the data comes from