Skip to main content
tapwater
England and Wales average 9.2

Tap water in CR4, MertonSafe to drink.Very hard.

Supplied by Thames Water. 76 samples, 23 substances, latest on 31 December 2025. Everything is inside the legal limit, and nothing comes close to it.

8.9 / 10

The tank is as full as the score. The specks are the minerals that make water hard.

What to do about it

Hard water: compare softener quotes

At 260 mg/L a softener is the only thing that stops limescale. Filters do not soften water.

It pays for itself in most homes at this hardness, through a boiler that stays efficient and appliances that last.

ZeroWater 10-Cup Jug

ZeroWater 10-Cup Jug

£40typical price

Households concerned about PFAS and heavy metals

Waterdrop 10UA Under Sink

Waterdrop 10UA Under Sink

£70typical price

High-volume under-sink filtration without RO complexity

We earn a commission if you buy through these links, at no extra cost to you. It never changes which product we put first. How we make money

Hear about it if CR4’s water changes

We check for supply incidents every fifteen minutes. If one affects CR4, you get an email the same day. You also get five short emails about your water over the first month.

Want this as a document?

Every result, the limits, hardness and what to do, as a PDF to keep with the house papers or send to a buyer or landlord. £19.99.

See the full report for CR4

What's in a glass of CR4 water

Every bubble is a substance the lab measured. The higher it floats, the closer it came to its legal limit, the dashed line at the top.

Nitrate came closest to a limit, at 57% of it. 18 of 19 substances used under a quarter of theirs.

0%25%50%75%limitLegal limitCopper: 0.02 mg/L, 1% of the 2 mg/L limitCopper1%Manganese: 0.0006 mg/L, 1% of the 0.05 mg/L limitManganese1%Selenium: 0.0005 mg/L, 1% of the 0.04 mg/L limitSelenium1%Iron: 0.007 mg/L, 3% of the 0.2 mg/L limitIron3%Aluminium: 0.0082 mg/L, 4% of the 0.2 mg/L limitAluminium4%Boron: 0.05 mg/L, 5% of the 1 mg/L limitBoron5%Nickel: 0.001 mg/L, 5% of the 0.02 mg/L limitNickel5%Chromium: 0.0025 mg/L, 5% of the 0.05 mg/L limitChromium5%Antimony: 0.0003 mg/L, 6% of the 0.005 mg/L limitAntimony6%Mercury: 0.00007 mg/L, 7% of the 0.001 mg/L limitMercury7%Nitrite: 0.04 mg/L, 8% of the 0.5 mg/L limitNitrite8%Cadmium: 0.0004 mg/L, 8% of the 0.005 mg/L limitCadmium8%Fluoride: 0.13 mg/L, 9% of the 1.5 mg/L limitFluoride9%Arsenic: 0.0009 mg/L, 9% of the 0.01 mg/L limitArsenic9%Colour: 1.9 mg/L Pt/Co, 10% of the 20 mg/L Pt/Co limitColour10%Bromate: 0.0012 mg/L, 12% of the 0.01 mg/L limitBromate12%Trihalomethanes: 0.016 mg/L, 16% of the 0.1 mg/L limitTrihalomethanes16%Lead: 0.0022 mg/L, 22% of the 0.01 mg/L limitLead22%Nitrate: 28.4 mg/L, 57% of the 50 mg/L limitNitrate57%
  1. Nitrate57%
  2. Lead22%
  3. Trihalomethanes16%
  4. Bromate12%
  5. Colour10%
  6. Arsenic9%
  7. Fluoride9%
  8. Nitrite8%
  9. Cadmium8%
  10. Mercury7%
  11. Antimony6%
  12. Boron5%
  13. Nickel5%
  14. Chromium5%
  15. Aluminium4%
  16. Iron3%
  17. Selenium1%
  18. Manganese1%
  19. Copper1%
  • Coliform Bacteria none found
  • E. coli none found
  • Conductivity 557 µS/cm
All 23 results as a table
SubstanceResultLegal limitShare of limit
Coliform Bacteria0 count/100mlMust be zeroNone found
E. coli0 count/100mlMust be zeroNone found
Colour1.9 mg/L Pt/Co20 mg/L Pt/Co
10%
Conductivity557 µS/cmNo legal limit–
Fluoride0.13 mg/L1.5 mg/L
9%
Nitrate28.4 mg/L50 mg/L
57%
Nitrite0.04 mg/L0.5 mg/L
8%
Hardness (as CaCO3)260 mg/LNo legal limit–
Aluminium0.0082 mg/L0.2 mg/L
4%
Antimony0.0003 mg/L0.005 mg/L
6%
Arsenic0.0009 mg/L0.01 mg/L
9%
Boron0.05 mg/L1 mg/L
5%
Cadmium0.0004 mg/L0.005 mg/L
8%
Chromium0.0025 mg/L0.05 mg/L
5%
Copper0.02 mg/L2 mg/L
1%
Iron0.007 mg/L0.2 mg/L
3%
Lead0.0022 mg/L0.01 mg/L
22%
Manganese0.0006 mg/L0.05 mg/L
1%
Mercury0.00007 mg/L0.001 mg/L
7%
Nickel0.001 mg/L0.02 mg/L
5%
Selenium0.0005 mg/L0.04 mg/L
1%
Trihalomethanes0.016 mg/L0.1 mg/L
16%
Bromate0.0012 mg/L0.01 mg/L
12%

260mg of limescale minerals in every litre

This is the water that furs up kettles

Very hard on the UK scale. It is fine to drink. It is hard on boilers, showers, skin and anything that heats water, and a jug or tap filter will not change that.

Soft400 mg/L

Over 200 mg/L, the building regulations guidance for England counts this as a hard water area: a new combination boiler or water heater should have limescale protection. The 200 ppm rule

Softener quotes for CR4

Leave your details and we will email you when we can match you with installers who cover CR4. No obligation.

A fitted softener typically costs £1,195 to £2,900. Prices by brand, with sources. Request a free assessment and we'll come back to you with local installer options for your area.

CR4— auto-detected from your search

100%

free, no obligation

shared only with your consent

Outside your tap

Your river is the Wandle (Croydon to Wandsworth) and the Graveney, rated moderate

The Environment Agency rated the Wandle (Croydon to Wandsworth) and the Graveney as moderate for ecological health in its 2025 assessment, meaning the river is noticeably changed by pollution or engineering. It is held back by phosphate and fish. It fails the chemical test, as every river, estuary and stretch of coast in England does, because of long-lasting pollutants such as mercury, PFOS (a forever chemical) and old flame retardants.

None of this is a test of your tap water. Environment Agency record · River health across England

Within 10 km

544

forever-chemical detections in nearby rivers and groundwater

At 3 sites. The highest was PFPeA at 0.018 µg/L, at Wandle at the Causeway, Wandsworth, 6.5 km away, in September 2024. These are river and borehole samples, not tests of your tap water.

Every PFAS sample around London · Which filters remove PFAS · PFAS explained

CR4 in short

Tap water in CR4 (Merton) is supplied by Thames Water in the Mitcham zone and scores 8.9 out of 10, against an England and Wales average of 9.2. None of the 23 tested substances came close to a limit. The latest sample is from 31 December 2025.

  • The lowest score of the 4 areas tested in MertonCR4 scores 8.9 out of 10. The best in Merton, SM4, scores 9.3.
  • Nitrate is the reading closest to its limit, at 57% of the 50 mg/L maximumIt passed with room to spare, and everything else tested sat further below its limit. See every reading
  • Very hard water at 260 mg/LThe threshold for very hard is 250 mg/L. Expect visible limescale on taps and in kettles in CR4. How hardness is measured

Questions about CR4 water

Is CR4 tap water safe to drink?

Based on the latest tests, CR4 (Merton) water scores 8.9/10, which is safe. 0 of 23 tested contaminants exceeded recommended levels. Water is supplied by Thames Water.

What contaminants are in CR4 water?

We tested 23 contaminants in CR4 water. None exceeded recommended safe levels. PFAS (forever chemicals) were also measured in rivers and groundwater within 10 km, though not in the tap-water tests themselves.

Who supplies water in CR4?

CR4 (Merton) is supplied by Thames Water. You can view their full profile and compliance data on our supplier page.

Is CR4 water hard or soft?

Water in CR4 (Merton) has a hardness of 260 mg/L CaCO3, which is classified as very hard. Hard water can cause limescale buildup. A water softener or filter jug may help.

Should I use a water filter in CR4?

CR4 water scored 8.9/10 with no contaminants above recommended levels. A filter is optional but can improve taste, especially if you notice a chlorine flavour. See our filter recommendations for your area.

Are there PFAS forever chemicals in CR4 water?

The tap-water tests we hold for CR4 do not include a PFAS result. Environment Agency monitoring found PFAS in 544 river and groundwater samples from 3 sites within 10 km of CR4, the highest being PFPeA at 0.018 µg/L about 6.5 km away. These are environmental samples, not tests of tap water. The UK currently has no legal limit for PFAS in drinking water; the Drinking Water Inspectorate uses a 0.1 µg/L guideline for individual compounds. Reverse osmosis filters can reduce PFAS levels.

How clean is the river near CR4?

The Environment Agency rated the Wandle (Croydon to Wandsworth) and the Graveney as moderate for ecological health in its 2025 assessment, meaning the river is noticeably changed by pollution or engineering. It is held back by phosphate and fish. It fails the chemical test, as every river, estuary and stretch of coast in England does, because of long-lasting pollutants such as mercury, PFOS (a forever chemical) and old flame retardants. This is a rating of the river, not of tap water in CR4, which is treated before it reaches homes.

Keep reading

PFAS explainedBoiling water taps and hard waterHow to test your waterBest water filtersFilter shower headsWater testing kitsUK water rankingsWater hardness checkerWater hardness map

River and groundwater readings near CR4

Environment Agency samples from rivers, groundwater and reservoirs nearby. Not your tap water. For scale they are shown against drinking water limits; rivers are judged against much stricter environmental standards, and on those every river in England fails for chemicals.

SubstanceReadingDrinking water limit
pH7.99 pHNone
Temperature9.9 °CNone
Conductivity663 µS/cmNone
Ammonia0.034 mg/L0.5 mg/L
Nitrate5.1 mg/L50 mg/L
Nitrite0.028 mg/L0.5 mg/L
Phosphate0.11 mg/LNone
Dissolved Oxygen10.7 mg/LNone
Copper0.00202 mg/L2 mg/L
Zinc0.0197 mg/LNone

Source: Thames Water test results, published through the Stream Water Data Portal; rivers and PFAS from the Environment Agency. Page updated . How we score · Where the data comes from